1. SYSTEM COMPATIBILITY . . . . . . . . 2
2. FEATURES . . . . . . . . . . . . . . . . . . 3
3. TOOLS REQUIRED . . . . . . . . . . . . . 3
4. SELECTING A LOCATION . . . . . . . . . 4
5. REMOVE OLD THERMOSTAT . . . . . . 5
6. MOUNT NEW THERMOSTAT . . . . . . 5
7. WIRING DIAGRAMS . . . . . . . . . . . . 6
8. HARDWARE SETUP OPTIONS . . . . 16
9. COMPLETE THE INSTALL . . . . . . . 18
10. FRONT PANEL ITEMS . . . . . . . . . . 19
11. OPERATING INSTRUCTIONS . . . . . 20
12. ADVANCED FEATURES . . . . . . . . . 24
13. PROGRAMMING . . . . . . . . . . . . . 29
14. BATTERIES AND MAINTENANCE . . . 30
15. TECHNICAL ASSISTANCE . . . . . . . 31
16. WARRANTY. . . . . . . . . . . . . . . . . 31
WARNING: Use Energizer
®
or DURACELL
®
Alkaline Batteries Only.
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
© 2008 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
TX9100E
SMART TEMP
®
UNIVERSAL PROGRAMMABLE THERMOSTAT
FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS
INSTALLATION AND OPERATING INSTRUCTIONS
IMPORTANT!
• Please read all instructions carefully before beginning installation
• Label the terminal designations on your existing wiring before
removing your existing thermostat
• Ignore the color of the wires since they may not comply with any
standard.
Thank you for your confidence in our product. To obtain the
best results from your investment, please read these
instructions and acquaint yourself with your purchase. Follow
the installation procedures carefully, and one step at a time.
This will save you time and minimize the chance of damaging
either the thermostat or the systems that it controls. These
instructions may contain information beyond that required for
your particular installation.
52032
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - SMART TEMP

1. SYSTEM COMPATIBILITY . . . . . . . . 22. FEATURES . . . . . . . . . . . . . . . . . . 33. TOOLS REQUIRED . . . . . . . . . . . . . 34. SELECTING A

Strany 2 - FAN TEMERATURE

10RC GRH YW2 W1A OBCFANA/CUNITSYSTEMXFMRTYPICAL 24-VOLT, 3 WIRE, CONVENTIONAL,1-STAGE COOLING ONLY SYSTEMSRCR5GFYC*6CFactory RH-RC Jumper Wire Install

Strany 3

11RC GRH YW2 W1A OBCFAN HEATERSYSTEMXFMRTYPICAL 24V, 4 WIRE, CONVENTIONAL HEATING AND COOLINGSYSTEMS WITH 1 STAGE HEAT AND 1 STAGE COOLA/CUNITRHRVGFYC

Strany 4 - CAUTION:

12RC GRH YW2 W1A OBCFANSYSTEMXFMRTYPICAL 24V, 5 WIRE, CONVENTIONAL HEATING AND COOLINGSYSTEMS WITH 2 STAGE HEAT AND 1 STAGE COOLHEATSECONDSTAGEHEATFIR

Strany 5

13RC GRH YW2 W1A OBCTYPICAL 24V, 4 WIRE, HEAT PUMP SYSTEMSWITH 1 STAGE HEAT AND 1 STAGE COOLFANSYSTEMXFMRHEATPUMPUNITCHANGE-OVERVALVE** Use either “O”

Strany 6

14RC GRH YW2 W1A OBCTYPICAL 24V, 5 WIRE, HEAT PUMP SYSTEMSWITH 2 STAGE HEAT AND 1 STAGE COOLFANSYSTEMXFMRHEATPUMPUNITCHANGE-OVERVALVE** Use “O” or “B”

Strany 7

15RC GRH YW2 W1A OBCFAN HEATERHEATXFMRTYPICAL 24V, 5 WIRE, CONVENTIONAL HEATING AND COOLINGSYSTEMS WITH 2 STAGE HEAT AND 1 STAGE COOL,WITH TWO 24-VOLT

Strany 8

168. HARDWARE SETUP OPTIONSNOTE:All of the settings, options, and components listed in thefollowing section are located on the rear of the thermostat,

Strany 9

17[1] SYSTEM MODEThis setting tells the thermostat about the type of heatingand cooling equipment that it is controlling, so that thesystem is operate

Strany 10 - RC GRH YW2 W1A OBC

18[4] SCALEThis setting determines how the thermostat displays alltemperatures on the screen. Switch position OFF is F°, andON is C°.[5] TIMEThis set

Strany 11

19NOTE:When you are finished performing your installation and setupoptions, please remove the thin plastic film that is protectingthe LCD display scre

Strany 12

21. SYSTEM COMPATIBILITYThe electrical rating for this thermostat is 1.5A per terminal,with a maximum of 2.0A for all terminals combined.COMPATIBLE WI

Strany 13

20needed. With the Fan switch in the ON position, the fan willoperate even when the Temperature Mode switch is in theOFF position to provide air circ

Strany 14

21buttons, adjust the clock to the current time, and make surethat the proper AM or PM indication is observed asappropriate. To assist with large adj

Strany 15

22TEMPERATURE OVERRIDEA Temperature Override occurs in Run mode, in either Heator Cool, anytime the user adjusts the set temperature to avalue that di

Strany 16

23EMERGENCY HEAT (Heat Pump Configuration Only)While in normal Heat mode with the rotary dial in the RUNposition, one single press of the COPY/EMER bu

Strany 17

24AIR FILTER MONITORIn systems that have a blower fan and air ducts, this featureis to assist you with proper maintenance and periodicreplacement of t

Strany 18 - WARNING:

25save energy in some cases. There is only one Swing setting,and this determines the cut-in and cut-out points for boththe first and second stages (i

Strany 19

26OFFSET: After the swing value has been accepted, the words“SET:” and “OFFSET” will be shown on the screen. Thissetting is shown as a number of degr

Strany 20

27LOCKING THE THERMOSTAT: Ensure the rotary dial is in theRUN position. Press the NEXT button for at least 2 seconds.The words “ENTER CODE” will appe

Strany 21

28CHANGING THE LOCK CODE: To create your own specificlock code, first ensure that the rotary dial is in the RUNposition. Press the NEXT button for at

Strany 22

2913. PROGRAMMINGSET HEAT PROGRAMRotate the dial to HEAT PROGRAM. You will beprogramming the heat periods for all seven days, one afterthe other star

Strany 23

32. THERMOSTAT FEATURES• Universal Compatibility (Conventional or Heat Pump)• 7 Day Programming• 4 Periods per Day• Quick Copy Programming• Exclusive

Strany 24

30will appear on the screen, with one of the days flashingabove. Using the UP/DOWN buttons, select the day that youwant to copy from. Press the NEXT

Strany 25 - ** = Only applies if a second

31swinging the body towards you, up and away from the base.Remove the used batteries from the battery tray and discardappropriately.Install two new En

Strany 26

Mt. Laurel, New Jersey 08054, USAhttp://www.luxproducts.com5:3672HEATTUDAYFPMlimitations on how long an implied warranty lasts, so theabove limitation

Strany 27

4CAUTION:This thermostat is protected against normal static electricdischarges; however touching a grounded metal objectbefore touching your thermosta

Strany 28

5• Your thermostat is a precision electronic instrument; pleasehandle it with care to avoid damage.5. REMOVE OLD THERMOSTAT1. Turn OFF the electricity

Strany 29

63. Remove the body from the thermostat’s base by pressingthe thumb latch at the bottom center of the unit andswinging the body away from the base.NOT

Strany 30

7• All of the dashed wires shown in the following wiringdiagrams are either optional, or their usage depends uponyour specific system type or brand.

Strany 31

8RC GRH YW2 W1A OBCFAN HEATERSYSTEMXFMRTYPICAL 24-VOLT, 2 OR 3 WIRE, CONVENTIONAL,1-STAGE, HEATING ONLY SYSTEMS (INCLUDING MILLIVOLT)GFRHRVCW1WH4Facto

Strany 32

9RC GRH YW2 W1A OBC3-WIREHYDRONICZONE VALVESYSTEMXFMRTYPICAL 24-VOLT, CONVENTIONAL, 1-STAGE, HOT WATERHEAT ONLY SYSTEMS WITH A 3-WIRE ZONE VALVEA6RHRV